Annular
phased array probes
Electronic focusing
Principle

Annular phased array probe for thick parts inspection

Convex annular array for rotor forged disc inspection
from the internal bore
|
Focusing depth can be electronically selected
More details about
phased array principle here >>
Adapted to all coupling methods
Typical work in pulse echo mode
Applications
Application requiring variable focus distance,
for example multi-zone inspection of plates, billet or other
pieces
Advantages
Reduction of the number of probes
Inspection depth variation speed (tuning, calibration)
Typical configurations
See also the main
features of all array probes here >>
| Freq. (MHz) |
Number of elements |
Total active diameter D
(mm) |
Max focus distance in water** (mm) |
Lateral resolution *** (mm) |
| 2 |
16 |
90 |
2700 |
1 to 24 |
| 5 |
16 |
60 |
3000 |
0.3 to 16 |
| 10 |
16 |
30 |
1500 |
0.2 to 8 |
| 15 |
16 |
15 |
600 |
0.15 to 4
|
Figures mentioned in the table are indicative
and may be adapted
** with total active aperture
*** achievable range of lateral resolution, depending on focal
distance and depth of field

10 MHz Annular phased array probe with removable wedge
|
Active elements pattern
|